CONVENTIONAL FIRE ALARM CONTROL PANEL CK1016

Wiring Smoke Detector
  • Wiring Smoke Detector
  • Addressable Smoke Heat Sensor
  • Fire manual call point switch alarm emergency
  • Conventional fire alarm systems
  • CONVENTIONAL FIRE ALARM CONTROL PANEL CK1016
Model No.︰CK1016
Brand Name︰Vedard
Country of Origin︰China
Unit Price︰US $ 250 / pc
Minimum Order︰1 pc
Share on:

 Total 17 Related Items 
Prev910111213Next

Product Description

This fire alarm control panel meets NFPA requirement. It should be installed, commissioned and maintained by suitably qualified service personnel. 
Description:
1. It has 16 zones and 4 sounder outputs.
2. It has 3 standard FORM-A relays contact for alarm, fault, supervisory. And it has EIA-485 port for communication with remote delay and repeater panel. 
3. It works with conventional N/O contact input devices including 2 wire, 4 wire smoke detector, heat detector, gas detector and call points etc. 
4. It can be programmed by panel keypad. It is supervised all wiring, AC voltage and battery level.
5. It is required to be connected to power earth and it self checks earth fault.
6. Max.20 detectors can be equipped in one zone. Each zone can be disabled separately. 
7. Output circuits:
24V resettable power output 1000mA
24V Nonresettable power output 1000mA
24V battery charger (up to 18AH battery)
8. EIA-485 port (interfaces to Annunciators, Graphic Annunciators and Remote Relay module)
9. 75VA power module is provided with the panel
10. Sound 1-4 output can be manual activate directly or disabled.
11. Panel running mode can be switched to manual or automatic.
12. It reports short and broken circuit of zones. 
13. It is designed with space of 2 pcs sealed lead-acid backup battery. 
14. It is with Test and disable function.
15. It can connect with Max.32 repeater panels by RS485 port.
Fire Security Project–Home Smoke Alarms
Specification:
1. Power supply:AC90~270VAC 50Hz 3A
2. Wire size: Minimum #14 AWG (2.0mm²) with 600V insulation.
3. Detector loop current is sufficient to ensure operation of 2 alarmed detectors per zone. Standby current: 7.26mA
4. Three relay output
relay contact rating: 2A at 30VDC
5. Total DC current output: 500mA
6. Recommend Max. standby current: 150mA
7. Input circuits 1-16 zones may be used as standard fire alarm control panel zones and accpet N/O contact devices.
8. Output circuits
24V resettable power output 1000mA
24V Nonresettable power output 1000mA
24V battery charger (up to 18AH battery)
EIA-485 port
9. Dimension: 35cm*40cm*16.5cm
It is with space of 7AH backup battery

Payment Terms︰Paypal
Product Image

Wiring Smoke Detector
Wiring Smoke Detector

Addressable Smoke Heat Sensor
Addressable Smoke Heat Sensor

Fire manual call point switch alarm emergency
Fire manual call point switch alarm emergency

Conventional fire alarm systems
Conventional fire alarm systems


Related Products
Garden burglaryproof DIY home security solar power wireless infrared light wall
Garden burglaryproof DIY home security solar power wireless infrared light wall
US $ 165
Intrusion detection outdoor security break beam system infrared grating alarm
Intrusion detection outdoor security break beam system infrared grating alarm
US $ 79
Residential Security Burglar Alarm System Wireless solar powered sensor
Residential Security Burglar Alarm System Wireless solar powered sensor
US $ 115
driveway security equipment solar photoelectric beams sensor
driveway security equipment solar photoelectric beams sensor
US $ 129




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !